I’ve been asked to teach a class at the University of Colorado at Denver (UCD) College of Architecture and Planning (CAP) on the topic of daylighting for buildings. It is just a single class session as part of a course on lighting design, taught by my friend Jill Perry. I thought a good way to start would be to see what AI thinks daylighting is for and here is a typical response from Microsoft Copilot:
Daylighting is a foundational sustainable design strategy that integrates building orientation, glazing, interior surfaces, and automated controls to optimize natural light for comfort, aesthetics, and energy efficiency.
I find this a reasonable definition, although I would add occupant productivity/satisfaction as an important benefit, and I would question the validity of energy efficiency. I find it surprising that many sources still describe daylighting buildings as an Energy Conserving Measure (ECM) as opposed to primarily a strategy to enhance human well-being. When I began daylighting buildings in the early 1980’s, it was still an effective ECM and many of my daylighted designs from that era returned a measurable improvement in energy efficiency.
In that era, however, interior electric lighting was almost exclusively fluorescent and average Lighting Power Densities (LPD’s) were in the range of 2-4 watts per square foot. Not only was that fluorescent lighting inefficient by today’s standards but it was also “hot.” In other words, it generated much waste heat for every lumen delivered. That resulted in the additional energy penalty of creating more demand on air conditioning systems to remove that extra waste heat.
The term efficacy (lumens per watt) describes this issue, with a typical incandescent bulb delivering only 12-18 lumens per watt, compact fluorescent 50-70 lumens per watt, linear fluorescent 60-100 lumens per watt, and LED up to 150 lumens per watt. Combined with advances in fixture design, modern LED lighting uses 15-20% of the energy needed for lighting a few decades ago. That has completely changed the dynamic of daylighting and building energy use.
Early Daylighting Design (circa 1983) by Paul Hutton, W. C. Muchow & Partners - Architect of Record
Today, we routinely design whole building lighting at 0.35 watts/s.f. or less. With only one-eighth the lighting power density to eliminate, the opportunity for energy savings from daylighting has largely disappeared. In fact, studies have shown that the energy penalty in additional heating and cooling from daylight apertures can easily overwhelm the slight savings from daylight harvesting.
Given this situation, I think a better way to describe daylighting and building energy use would be to state that “careful design of daylighting apertures and coordination with electric lighting and controls are critical to avoid increasing building energy use related to daylighting.” The use of automatic lighting controls to turn off or dim lights, as required by all major Building and Energy Codes, is an important design strategy and is widely accepted and implemented. Without those controls, daylighting strategies would inevitably increase energy use.
Even though daylighting cannot deliver building energy savings the way it did decades ago, I am still a fervent advocate of abundant daylighting for most building types. I do so because daylighting, along with the views of the ground and sky that daylight apertures introduce, improves life for occupants of daylighted building in these realms.
Cognitive performance
Circadian rhythm and sleep hygiene
Mental health
We could analyze the mechanisms behind these improvements, but that is a more complex story and will have to wait for another time.
#Daylighting #UCDCollegeOfArchitectureAndPlanning #EnergyConservingMeasure